Water leaking around the furnace - On-Site Today, Diagnosis First

Same-day diagnosis with the repair price given before any work starts, and an honest repair-versus-replace answer when the system is near the end of its life.

✓ Licensed & Insured ✓ Written quotes ✓ Permits handled
Call Now - 24/7 Dispatch

We answer around the clock

🛡 Licensed & Insured 📝 Written Fixed-Price Quotes 💲 No Change Orders · Free Estimates
Every visit starts with

Seasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed

Your new heating and cooling system for as low as $119/month*on approved credit; ask for current terms

Diagnosis first, numbers second - you approve the repair price before a single part goes in.

Styles & brands we work with

AC repair
AC repair
Furnace & heating
Furnace & heating
Heat pumps
Heat pumps
Ductless mini splits
Ductless mini splits
Carrier
Carrier
Trane
Trane
Goodman
Goodman

Before & after – our own jobs

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Water Leaking Around the Furnace

Water pooling near your furnace almost always means one of three things: a blocked condensate drain, a cracked condensate pan, or a secondary heat exchanger problem on a high-efficiency unit. None of these are something you should ignore, and one of them – the heat exchanger – carries a genuine safety concern beyond the puddle you’re looking at right now.

Call (984) 538-9003

Here’s the plain version of what’s going on. High-efficiency furnaces (the kind rated 90% AFUE or higher) produce water as a byproduct of combustion. That water is supposed to flow out through a condensate drain line. When that line clogs, cracks, or the drain pan underneath fails, the water has nowhere to go but the floor. If your furnace is an older, standard-efficiency unit and you’re seeing water, the source is usually something else entirely – a humidifier mounted to the unit, a leaking flue pipe, or, in some cases, an AC coil drain that shares the same drain line and is backed up. A technician can tell within a few minutes which one it is, because the source and the smell of the water are different in each case.

Why It Happens

Clogged or Cracked Condensate Drain Line

This is the most common reason a high-efficiency furnace leaks. Over a heating season, algae, dust, and mineral deposits build up inside the small plastic condensate drain line until water backs up and overflows. You’ll usually see a slow, steady drip or a shallow puddle directly below the furnace’s white PVC drain tubing. The water is typically clear or faintly cloudy.

Failed Condensate Pan or Pump

Beneath the coil on a high-efficiency furnace sits a shallow plastic drain pan. It can crack from age, freeze damage, or simple wear – and when it does, water escapes before it ever reaches the drain line. Some setups also use a small condensate pump to move water to a drain. If that pump’s float switch fails or the pump itself stops working, water backs up and spills over the edge of the pan. If you see the puddle forming directly under the unit’s base, rather than along the drain line, the pan or pump is the likely culprit.

Secondary Heat Exchanger Crack

This one matters more than a wet floor. The secondary heat exchanger on a high-efficiency furnace extracts the last heat from combustion gases – which is how those systems reach 90%+ efficiency. If this component cracks, it can allow combustion byproducts, including carbon monoxide, to mix with the air being distributed through your home. Water leaking from inside the furnace cabinet, rather than from drain components on the outside, can indicate this failure. If your carbon monoxide detector has gone off, or anyone in the house has had unexplained headaches or dizziness, stop the furnace at the thermostat and call immediately. Do not try to inspect the heat exchanger yourself.

Humidifier or AC Coil Drain Overflow

Many furnaces have a whole-house humidifier mounted directly on the supply plenum. These have their own water feed line and drain, and when either fails, the water runs straight down to the furnace base and looks exactly like a furnace leak. Similarly, if your air handler shares a condensate drain line with the furnace and that line is partially blocked, warm months of AC use can cause enough back-pressure that water migrates backward toward the furnace. The giveaway here is timing: if the leak appeared or worsened when the humidifier was running, or when you recently switched from cooling to heating, one of these two sources is almost certainly responsible.

What to Do Right Now

  • Turn the furnace off at the thermostat. Switch it from Heat to Off. This stops the water production at the source and gives you a dry look at what’s already accumulated.
  • If you have a carbon monoxide detector and it has alarmed, leave the house now. Get everyone out, leave the door open, and call 911 before you call anyone else. A water leak alone does not mean CO is present, but a cracked secondary heat exchanger can produce both. Do not go back inside to investigate.
  • Take photos before you clean up the water. Where exactly is it pooling? Is it coming from a drain tube, the base of the unit, or the area around the flue pipe? A photo of this takes thirty seconds and helps your technician arrive with the right parts.
  • Do not attempt to open the furnace cabinet or touch the condensate pump wiring. The components inside a furnace cabinet carry live voltage, and the heat exchanger area is not safe to probe without proper equipment and training.
  • Put down towels to protect flooring, but don’t use a shop vac on any standing water near the unit until power to the furnace is confirmed off at the breaker. Water and live electrical components in the same cabinet is a real hazard, not a theoretical one.

How We Fix It

When your local Brandt HVAC technician arrives, the first thing they do is a visual trace – following the water back to its actual source before touching anything. That trace usually takes ten to fifteen minutes and tells them whether this is a drain issue, a pan or pump failure, or something internal to the heat exchanger.

If it’s a condensate drain clog, they’ll clear the line, flush it, and inspect the trap. If the condensate pan is cracked, it gets replaced. If the pump has failed, it gets tested and swapped out. If the heat exchanger warrants a closer look, they’ll use the proper diagnostic tools – not a visual guess – before giving you a conclusion you can actually rely on.

This work falls under our Furnace Repair service. Before any part is ordered or any work starts, you’ll have a written price in hand. That’s not a policy we sometimes follow – it’s how every single Brandt HVAC job works, every time. If anything we repair fails during the guarantee period, we come back at no charge under the 365-Day Done Right Promise. Most drain and pan repairs are completed in a single visit.

Frequently Asked Questions

Get It Fixed

Call (984) 538-9003 – a live person answers around the clock – or book online. Your local Brandt HVAC team will send a background-checked, uniformed technician with a written price in hand. No work starts until you’ve seen and agreed to the cost.

Written by Devin Marlowe, Owner and Lead HVAC Technician, Brandt HVAC – part of the Threshold Group family since 2003.

What Our Customers Say

★★★★★ 5.0 from 9+ reviews

"Knowing a vetted tech was coming into my house made a difference. Name and photo texted ahead, shoe covers, polite, and thorough with explaining."

- Tina M.

"Drain line was clogging and causing a leak by the air handler. They cleared it and installed a float switch so it can't flood again."

- Nora T.

"AC stopped cooling on a hot afternoon. Tech arrived with a badge, checked the capacitor, found it bad, and replaced it on the spot. House cooled down within the hour."

- Steve P.
Need HVAC help nationwide? Licensed & insured · 30-60 min response · free estimates
Call (984) 538-9003

Current Offers

Bring these savings to your next appointment.

10%

10% Off Your First Service Visit

Valid on your first completed service visit with us.

Expires Mar 31, 2027
Always

Written Price Before Any Work Starts

Expires Mar 31, 2027
Included

Written Guarantee on Every Repair

Expires Mar 31, 2027
Free

Free Second Visit if the Repair Fails

Expires Mar 31, 2027

Request a Free Estimate

Tell us what's going on in Los Angeles - we'll get back to you fast. No obligation.

When you submit this form, you accept our Privacy Policy and authorize us to contact you by phone, email, or text about your request, including by the independent contractors we may refer it to.

Call Now - 24/7 Dispatch
Areas We Serve
Call Now - 24/7 Dispatch